Article

The Importance of Industrial Dehumidifier in Battery Damp proof

SIAL
The importance of batteries in modern society is irreplaceable, especially in China, which ultimately has a high demand for electric vehicles in the world. The key energy source for promoting electric vehicles is batteries, let alone new energy electric vehicles. There are many types of batteries, mainly including aluminate batteries, UPS batteries, Lithium iron phosphate battery and extraordinary batteries. The consumption of strong alkaline batteries has been relatively low, and now Lithium iron phosphate battery are the most used batteries.
The harm of batteries is extremely great. If discarded outdoors, the surface of the battery will corrode under the sun and rain. The heavy metals contained in the waste battery, such as mercury, cadmium, manganese, and lead, will exceed the standard and seep into the soil and surface water, causing pollution to land resources. Once people consume food crops made from contaminated new land or drink contaminated water, these toxic substances, such as heavy metals, will enter the human body if they exceed the standard, Gradually accumulating, it poses a great threat to human health. It should be remembered that a single button battery can pollute 600000 liters of water, indicating the harm of batteries.
Moreover, the battery will not only destroy land resources, but also cause Corrosive substance and organic gases if the battery is corroded during storage, which will also affect the physical and mental health of surrounding people. So for battery warehouses, it is very important to avoid corrosion on the surface of the battery. The corrosion of items in the environment is very rare due to strong acids and alkalis, but it is only due to dampness and cold. Therefore, it is important to prevent dampness in the battery warehouse and ensure that it is comfortable and ventilated.
So how can we ensure that the relative humidity of the air in the battery warehouse is not too high? At this point, it is necessary to start with the details. First, close the windows to avoid getting wet and cold from the windows. Then, when entering the storage room, remove and replace shoes, especially when it rains. Do not bring water vapor into the warehouse when entering, so fold umbrellas and other things and do not bring them to the battery warehouse. And it should be noted that the exhaust system installed for ventilation should also be turned off when it rains.
The second and most important point is to equip the battery warehouse with industrial Dehumidifier, which is also a machine for technical professionals to deal with wet and cold conditions. The company can also equip sufficient industrial Dehumidifier according to the area of the site where the batteries are stored to prevent moisture and humidity and reduce the relative humidity of the air, so there is no need to worry about the occurrence of moisture regain and corrosion of the batteries, resulting in battery damage.

Precautions for use of industrial Dehumidifier

Timely dehumidification will make the natural environment more and more comfortable, and also not easy to grow damp and mildew. Dehumidifier seems to be an essential household appliance product for many families and enterprises today. Dehumidification on time will not only be much more comfortable, and machines and equipment are not easy to mildew, but there are also many small details to consider when using the Dehumidifier.
1. Usage duration

If you want to travel, you can run the Dehumidifier. It just doesn't matter if you need to stay inside during the dehumidification process, there won't be any impact. Just if you feel your skin is getting dry, you need to turn off the Dehumidifier to prevent your skin from feeling uncomfortable.

2. Placement of

Because the Dehumidifier contains a water collecting tank, it should be placed in the middle of the room during use. If you want to get close to the wall, it is advisable to always maintain a spacing of 10-15 centimeters, and never lean against the foot of the wall.

3. Pay attention to air humidity

The Dehumidifier works gradually when the room is wet. Generally speaking, the corresponding environmental humidity should be maintained between 50-60 degrees Celsius as much as possible, so that the growth of dust mites will also slow down. Just don't excessively dehumidify, if the gas is damp below 30 degrees, it will be too dry and irritable.

4. Storage capacity at full load

On the premise that the Dehumidifier absorbs nutrients, the water level of the water collecting tank will rise simultaneously and reach the full water level, some dehumidifiers will automatically exit or prompt the user. At this point, remember to first unplug the power and unplug the power plug, and then throw away the water after a while. Otherwise, when immediately removing the water storage tank to refill, the water inside may drip into the room due to not being caught by the tank.

5. Clean the filter screen on time

After the Dehumidifier has been used for a period of time, it is also necessary to regularly maintain the filter screen inside the equipment. If the dust is large, don't forget to clean it. Due to the larger amount of dust absorbed by the filter screen, it can also affect the dehumidification efficiency.
1 Comments
Leave a Comment
Your email address will not be published. Required fields are marked *
Submit Comment
Latest Exhibtions
Contact Now
Name:
Email:  Email is wrong!
Message:  Message is wrong!
SUBMIT
Contact us now
Forced Air Heater for Sale - Sial Heater
Am Seestern 840547 dusseldorf, Germany
Innovation, quality, service
Committed to technological innovation and quality improvement, Provide efficient and intelligent climate solutions to customers around the world.
© 2020 Sial        SiteMap.html    SiteMap.xml    Terms of Service      Privacy Policy
Marketing Support by Globalsir
Enter your inquiry details, We will reply you in 24 hours.
Name can't be empty
E-mail can't be empty
Company can't be empty
Phone can't be empty
Products can't be empty
Message can't be empty
Verification code error
code
Clear